WASTEWATER REUSE REVERSE OSMOSIS MACHINES

The N-Series (WE) packaged system has been designed at optimal low-flux for wastewater reuse applications (i.e. tertiary UF treatment). This new platform is a perfect fit to polish UMT UF-XE and UF Tech Series and Tertiary packaged plants effluents. packaged engineered solutions built to polish UF permeate for reuse

• Special wastewater design based on the experience of custom UF and RO combination.
• Speed of delivery.
• Modular design to operate as a complete water treatment system, or as a stand-alone component.
• membranes option for higher fouling potential wastewater.

#
N-18 WE N-36 WE N-54 WE N-72 WE
Operating Temperature Range (°C) 2 to 30
Feed Pressure (kPa) 207 to 414
Feed Rate (m3/d) 398 801 1199 1597
Permeate Rate (m3/d) 300 600 899 1199
Concentrate Rate (m3/d) 98 201 300 398
Power Options Voltage 400/480 V, 3 phase, 50/60 Hz
Membrane Quantity 18 36 54 72
Membrane Housing Style 6 element long, 4 port
Housing Quantity 1 2 3
Cartridge Filter Quantity 7 per change out
Cartridge Filter

Quantity per Housing

7 14 21